    Nickel-metal hydride batteries can be completely replaced by a one-time battery, especially when used for Gao Haodian equipment. We need not completely ignore basic nominal 1.5 V, a nominal 1.2 V rechargeable laptop battery the difference, since both balanced discharge voltage level is basically the same and alkaline batteries compared to the price of rechargeable batteries appear to be relatively high, But also to purchase an additional battery charger, naturally spend more, but rechargeable batteries can be recycled as many as 500-1000 times, so in the long run, rechargeable batteries cost-effective than alkaline batteries and environmental protection! Due to nickel-cadmium batteries containing hazardous substances - cadmium, nickel-hydrogen capacity than half of small, there are obvious memory effect, so as nickel-hydrogen battery production technology development, nickel-cadmium batteries have gradually been eliminated by

    The primary use of rechargeable batteries: the purchase of new or prolonged storage is not used for the first several charge because of lack of pavilion battery, battery charging and discharging performance of non-normal reaction, so if the use of the smart charger, it is likely charger Unable to accurately judge the first few are likely to charge less it seems normal, but it is not smart charger encountered when normal cells the normal reaction, we need not worry, rechargeable battery-activated several times, filling Discharge will be back to normal. If this situation, you are the smart charger that does not understand the reaction, then I can only suggest you use ordinary non-smart slowly filling the category to maintain a battery or two (fully charged, and then use or discharge End End For a maintenance), after maintaining a two-for-use smart charger, should be able to see the smart charger a normal reaction.

    Charge: Select charger, it is best to use those with the right to terminate charging devices (such as the Anti-time installation charge of negative voltage difference (- dV) cut off the charge and the prevention of overheating sensor devices) charger, so as not to charge the battery because of the shortened Life. In general, the standard charge (about four hours of -10 hours) than the ultra-fast charge (about ¡Ü 1 hour) to extend F2024A life.

      Discharge: the depth of discharge impact on battery life is the main factor, in general, the battery voltage discharge in the closing 0.8 to 1.0 volts (as discharge, the battery voltage will usually rebound within a few minutes to more than 1.1 V), are acceptable The scope. If the battery discharge at a high temperature, will shorten battery life. Battery charging time required ¡Ö battery capacity / x 120% charge current general charging time will be the basis for the charge current big - small increase 10 - 60 percent, to recharge during the preparation of the efficiency losses. Nickel-metal hydride batteries more appropriate charge current is 0.1 C-0.5C, more than 2 C or less than 0.1 C of the charge current may affect F2024B performance and shorten battery life.

      The battery charge or a discharge, will lead to reduced battery performance, poor performance. Nickel-metal hydride batteries: 1, not depth of discharge, is prohibited by the lamp or resistance to the battery to discharge completely electricity! 2, is prohibited on just the battery fully charged again forcibly charging 3, prolonged power shortage can not be saved, it should be kept charging, and suggested that the long-term use of batteries to charge every three months in order to avoid an electric short circuit, batteries and coins will not Or keychain and other metal items together on the same pocket, to make full use of F2299A storage box.

    Or rechargeable batteries in the discharge period is certainly a fever, because there is no conversion efficiency of 100% of the charger or rechargeable batteries, certainly greater than the energy consumption of the actual battery storage of energy, the energy consumption of> up the chemical storage batteries Can. Ability to follow the conservation, more energy will not be a vacuum disappeared, but the discharge into heat, so that the battery is stored chemical energy into heat, if the fever is not, it can only show that the Pavilion DV1000 battery, nickel-hydrogen After the battery is full, not shelved, it will gradually lose energy, we called self-discharge.

    In general, nickel-hydrogen batteries at room temperature for the self-discharge rate of about a month from 15 to 20 percent. To fully extended battery life, it should be: the battery stored in a cool, dry, well-ventilated places, avoid direct sunlight. To long-term storage, the environmental temperature should be below 30 degrees Celsius. Not in very high or extremely low temperatures and the use of charge. Save the higher the temperature, nickel-hydrogen battery, the easier it is the loss of capacity, that is, the greater the battery self-discharge without refrigeration, at room temperature only stored in a dry environment to use high-quality Charger, a necessary and sufficient to minimize the situation . With the right to use rechargeable monitoring the charger. Best regularly charge the Pavilion ZV5000 battery and discharge to prevent the battery voltage dropped to less than 0.8 volts. If the use of electronic equipment will not be a long time, to remove the battery or switch off the equipment. Do not different chemical structure, different brands, different capacities, different levels of charge, at different times to buy the used batteries.